CNT-600-FR, CNT® 50 Ohm Braided Coaxial Cable, black non-halogenated, fire retardant polyolefin jacket, Dca s2 d2 Compliant
Specifications
Product Classification
Product Type |
Braided coaxial cable |
Product Brand |
CNT® |
Product Series |
CNT-600 |
General Specifications
Braid Coverage |
90 % |
Cable Type |
CNT-600 |
Jacket Color |
Black |
Dimensions
Diameter Over Dielectric |
11.56 mm | 0.455 in |
Diameter Over Jacket |
14.99 mm | 0.59 in |
Inner Conductor OD |
4.47 mm | 0.176 in |
Outer Conductor OD |
12.5 mm | 0.492 in |
Nominal Size |
0.600 in |
Electrical Specifications
Cable Impedance |
50 ohm |
Capacitance |
76 pF/m | 23.165 pF/ft |
dc Resistance, Inner Conductor |
1.74 ohms/km | 0.53 ohms/kft |
dc Resistance, Outer Conductor |
3.94 ohms/km | 1.201 ohms/kft |
dc Test Voltage |
4600 V |
Jacket Spark Test Voltage (rms) |
8000 V |
Maximum Frequency |
10.2 GHz |
Operating Frequency Band |
30 – 6000 MHz |
Peak Power |
40 kW |
Shielding Effectiveness |
90 dB |
Velocity |
87 % |
Attenuation
Frequency |
Attenuation (dB/100 m) |
Attenuation (dB/100 ft) |
30.0 MHz |
1.600 |
0.490 |
50.0 MHz |
1.970 |
0.600 |
150.0 MHz |
3.200 |
0.970 |
220.0 MHz |
3.800 |
1.170 |
450.0 MHz |
5.600 |
1.710 |
900.0 MHz |
8.200 |
2.500 |
1500.0 MHz |
10.800 |
3.300 |
1800.0 MHz |
12.100 |
3.700 |
2000.0 MHz |
12.800 |
3.900 |
2400.0 MHz |
14.440 |
4.400 |
2500.0 MHz |
14.800 |
4.500 |
3000.0 MHz |
16.400 |
5.000 |
4000.0 MHz |
19.360 |
5.900 |
4500.0 MHz |
21.000 |
6.400 |
5000.0 MHz |
22.310 |
6.800 |
5200.0 MHz |
22.970 |
7.000 |
5500.0 MHz |
23.620 |
7.200 |
5800.0 MHz |
24.280 |
7.400 |
6000.0 MHz |
24.930 |
7.600 |
Material Specifications
Braid Material |
Tinned copper |
Dielectric Material |
Foam PE |
Jacket Material |
Non-halogenated, fire retardant polyolefin |
Inner Conductor Material |
Copper-clad aluminum wire |
Shield Tape Material |
Aluminum |
Mechanical Specifications
Minimum Bend Radius, Single Bend |
38.1 mm | 1.5 in |
Tensile Strength |
159 kg | 350.535 lb |
Bending Moment |
3.7 N-m | 32.748 in lb |
Flat Plate Crush Strength |
1.1 kg/mm | 61.597 lb/in |
Environmental Specifications
Installation temperature |
-40 °C to +60 °C (-40 °F to +140 °F) |
Operating Temperature |
-40 °C to +60 °C (-40 °F to +140 °F) |
Storage Temperature |
-40 °C to +60 °C (-40 °F to +140 °F) |
EN50575 CPR Cable EuroClass Fire Performance |
Dca |